Cerca tra vari insegnanti di Inglese...
China flagAmy
an abstract of my paper here is an abstract of my thesis.I wish someone could help me with my errors. thank u!! BaCe0.7In0.3-xTaxO3–δ powders were synthesized by modified citrate method. The powders were pressed into pellets, and then sintered at 1150℃,1250℃ and 1350℃, respectively. The samples were characterized by X-ray diffraction,scanning electron microscopy and the conductivity was measured by A.C. impedance method. The results indicate that the porosities of the samples sintered at 1350℃ are less than 10% and the sinterability increased with the increase of In-doping. In dopant could improve the stability of the powders to against water but has little effect to against CO2. The tolerance to CO2 was largely improved with In-Ta co-doped and increased with the increase of Ta-doping. However the conductivities in wet H2 decreased with the increase of Ta-doping. A conductivity of 1.16 10-3s/cm was obtained for the BCI25T5 sample at 800 °C in wet 10% H2 atmosphere.

Correzioni · 2

0

an abstract of my paper

Here is an abstract of my thesis.I wish someone could help me with my errors. thank u!!
(BaCe0.7In0.3,   -xTaxO3,   –δ?) powders were synthesized by (a/the)* modified citrate method. The powders were pressed into pellets, and then sintered at 1150℃,1250℃ and 1350℃, respectively. The samples were analysed(?) by X-ray diffraction, scanning electron microscopy and the conductivity was found as the reciprocal of their A.C. impedance. The results indicate that the porosities of the samples sintered at 1350℃ are less than 10%(10 percent of what?) and the sinterability increased with the increase of In-doping. (In dopant could improve the stability of the powders to against water? I don't understand) but had little effect (to against? I don't understand) CO2. Tolerance to CO2 was largely improved with In-Ta co-doped(co-doping?) and increased proportionally to** Ta-doping. However the conductivities in wet H2 decreased with the increase of Ta-doping***. A conductivity of 1.16 10-3s/cm was obtained for the BCI25T5 sample at 800 °C in wet 10% H2 atmosphere.

*is this a standard method? If yes, then 'the'. If no then 'a'.

**directly proportionally, or, as one increased the other increased monotonely?

***was one inversely proportional to the other?

Vuoi progredire più velocemente?

Unisciti a questa comunità di apprendimento e prova gli esercizi gratuiti!

Non perdere l'opportunità di imparare una lingua comodamente da casa tua. Esplora la nostra selezione di insegnanti di lingue esperti e iscriviti subito alla tua prima lezione!

Inizia a imparare oggi